Description
SCS 770758 - Dual Combination Tester
SCS 770758 - Dual Combination Tester
- Tests operator’s path-to-ground; wrist strap limits 750 kilohms to 10 megohms; footwear limits 750 kilohms to 35 megohms
Meets ANSI/ESD S20.20 Table 2 Personnel Grounding Requirement testing per ESD TR53. - Relay terminal
Pairs with a turnstile, automatic door or other locking system to control access to ESD Protected Areas. - Simultaneous testing in less than 3 seconds
Reduces time spent testing personal grounding devices used in ESD Control Plans. - Solid-state test switch with no moving parts
Maintains accuracy of tests and extends the lifetime of the tester. - Split foot plate for testing foot grounders (or shoes)
Tests both foot grounders independently at the same time. - Calibration unit available for accurate performance and conformity testing in the factory, 770751.
- 100-240VAC power adapter with interchangeable plugs
Works with standard electrical systems in North America, United Kingdom, Japan, Asia and Europe. - NIST calibrated with certificate included
Calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology.
Product ID : 770758
Housing Height : 11.35 Inch
Housing Length : 7.75 Inch
Housing Width : 1.47 Inch
Input Voltage and Frequency (External Adapter) : AC/DC Power Adapter
Power Output : 12VDC, 0.5A
Cable Length : 6 ft. (1.83 m)
Operating Temperature : 70°F to 85°F (21°C to 30°C) for 1 gigohm test limit; 41°F to 85°F (5°C to 30°C) for all other test limits
Environmental Requirements : Indoor use only at altitudes less than 6500 ft. (2 km) Maximum relative humidity of 80% up to 85°F (30°C) decreasing linearly to 50% @ 85°F (30°C) Maximum relative humidity of 50% at 1 gigohm setting
Test Accuracy : ±20% for 1 gigohm footwear test limit; ±10% for all other test limits
Test Switch Voltage : 5 VDC @ open circuit
Wrist Strap and Footwear Test Voltage : 30 VDC @ open circuit; Test current is limited by resistors and varies on the test range setting (100 kilohms - 1 gigohm)
Relay Contact Rating : 1A @ 30VDC max
Harmonizing Code : 9030330040
ECCN : EAR99
Housing Height : 11.35 Inch
Housing Length : 7.75 Inch
Housing Width : 1.47 Inch
Input Voltage and Frequency (External Adapter) : AC/DC Power Adapter
Power Output : 12VDC, 0.5A
Cable Length : 6 ft. (1.83 m)
Operating Temperature : 70°F to 85°F (21°C to 30°C) for 1 gigohm test limit; 41°F to 85°F (5°C to 30°C) for all other test limits
Environmental Requirements : Indoor use only at altitudes less than 6500 ft. (2 km) Maximum relative humidity of 80% up to 85°F (30°C) decreasing linearly to 50% @ 85°F (30°C) Maximum relative humidity of 50% at 1 gigohm setting
Test Accuracy : ±20% for 1 gigohm footwear test limit; ±10% for all other test limits
Test Switch Voltage : 5 VDC @ open circuit
Wrist Strap and Footwear Test Voltage : 30 VDC @ open circuit; Test current is limited by resistors and varies on the test range setting (100 kilohms - 1 gigohm)
Relay Contact Rating : 1A @ 30VDC max
Harmonizing Code : 9030330040
ECCN : EAR99