Description
SCS D300424 - 4 in x 24 in, 6 Mil Dri-Shield 3000 Series Moisture Barrier Bag, 100 Bags Per Pack
0.006" (6 mil) Thick Bag constructed from layers of nylon, foil, and polyethylene
Designed for moisture and electrostatic discharge (ESD) sensitive items (such as SMT). Meets ANSI/ESD S20.20, ANSI/ESD S541, ANSI/ESD S11.4 Level 1, and IPC/JEDEC J-STD-033.
< / = 0.0003 Grams Moisture Vapor Transmission Rate (MVTR)
Designed for dry packing of moisture sensitive devices and to protect contents from damage due to ESD events or EMI.
Nylon Reinforcement Layer
Ideal choice for packaging products with sharp corners. Strengthens bag structure to maintain performance per ASTM F392 flex testing and meets the ANSI/ESD S541 requirement as a barrier to current flow.
<10 nJ Energy Penetration Tested per ANSI/ESD STM11.31
Protects contents from ESD charges and discharges. Meets the requirement for discharge shielding per Static Control Bag ANSI/ESD S11.4 Level 1.
>16lb Puncture Strength Average
Provides physical protection for contents.
Dissipative Inner and Outer Surfaces Rs 1 x 104 to < 1 x 1011 ohms per ANSI/ESD STM11.11
Allows bag to be grounded when placed on a grounded surface or handled by a grounded operator.
Printed with ESD Protective Symbol, Moisture Sensitive Warning Symbols and Lot Code Information
Meets the requirements of ANSI/ESD S541 for quality control purposes.
SCS D300424 - 4 in x 24 in, 6 Mil Dri-Shield 3000 Series Moisture Barrier Bag, 100 Bags Per Pack
- Provides protection for ESD sensitive and moisture sensitive electronics, typically SMT (Surface Mount Technology) items.
- Best practice is to use with Desiccant and a Humidity Indicator Card. A nylon layer helps to strengthen the bag.
- The bags are heat sealable and suitable for vacuum packaging.
- Bags are printed with ESD protective and moisture sensitive warning symbols, and a lot code for traceability.
0.006" (6 mil) Thick Bag constructed from layers of nylon, foil, and polyethylene
Designed for moisture and electrostatic discharge (ESD) sensitive items (such as SMT). Meets ANSI/ESD S20.20, ANSI/ESD S541, ANSI/ESD S11.4 Level 1, and IPC/JEDEC J-STD-033.
< / = 0.0003 Grams Moisture Vapor Transmission Rate (MVTR)
Designed for dry packing of moisture sensitive devices and to protect contents from damage due to ESD events or EMI.
Nylon Reinforcement Layer
Ideal choice for packaging products with sharp corners. Strengthens bag structure to maintain performance per ASTM F392 flex testing and meets the ANSI/ESD S541 requirement as a barrier to current flow.
<10 nJ Energy Penetration Tested per ANSI/ESD STM11.31
Protects contents from ESD charges and discharges. Meets the requirement for discharge shielding per Static Control Bag ANSI/ESD S11.4 Level 1.
>16lb Puncture Strength Average
Provides physical protection for contents.
Dissipative Inner and Outer Surfaces Rs 1 x 104 to < 1 x 1011 ohms per ANSI/ESD STM11.11
Allows bag to be grounded when placed on a grounded surface or handled by a grounded operator.
Printed with ESD Protective Symbol, Moisture Sensitive Warning Symbols and Lot Code Information
Meets the requirements of ANSI/ESD S541 for quality control purposes.
Product ID : D300424
Moisture Vapor : < 0.0003 grams/100 sq. in./24 hrs; ASTM F1249
Transmission Rate (MVTR) : < 0.002 grams/100 sq. in./24hrs; ASTM F392 condition E and ASTM F2149
Tensile Strength : 3800 PSI, 26 MPa; ASTM D882
Puncture Resistance : 16 lbs, 71; N MIL-STD-3010C Method 2065
Seal Strength : 15 lbs, 66; N ASTM D882
Thickness : 6 mils, 0.006" +/-10%; MIL-STD-3010C Method 1003
Marking Adhesion : Pass; IPC-TM-650 2.4.1
ESD Shielding : <10 nJ; ANSI/ESD STM11.31
Surface Resistance - Interior : 1 x 104 to < 1 x 1011 ohms; ANSI/ESD STM11.11
Surface Resistance - Exterior : 1 x 104 to < 1 x 1011 ohms; ANSI/ESD STM11.11
EMI Attenuation : 45 dB; 1 to 10 GHz
Silicone : Not Detected; FTIR
Temperature : 400°F, 204°C
Time : 0.6 – 4.5 seconds
Pressure : 30 – 70 PSI, 206 – 482 KPa
Moisture Vapor : < 0.0003 grams/100 sq. in./24 hrs; ASTM F1249
Transmission Rate (MVTR) : < 0.002 grams/100 sq. in./24hrs; ASTM F392 condition E and ASTM F2149
Tensile Strength : 3800 PSI, 26 MPa; ASTM D882
Puncture Resistance : 16 lbs, 71; N MIL-STD-3010C Method 2065
Seal Strength : 15 lbs, 66; N ASTM D882
Thickness : 6 mils, 0.006" +/-10%; MIL-STD-3010C Method 1003
Marking Adhesion : Pass; IPC-TM-650 2.4.1
ESD Shielding : <10 nJ; ANSI/ESD STM11.31
Surface Resistance - Interior : 1 x 104 to < 1 x 1011 ohms; ANSI/ESD STM11.11
Surface Resistance - Exterior : 1 x 104 to < 1 x 1011 ohms; ANSI/ESD STM11.11
EMI Attenuation : 45 dB; 1 to 10 GHz
Silicone : Not Detected; FTIR
Temperature : 400°F, 204°C
Time : 0.6 – 4.5 seconds
Pressure : 30 – 70 PSI, 206 – 482 KPa